API-8/232 Specifications

API-8/232 Product Description
API-8/232 Manual
API-8/232 Diagrams
API-8/232 Software
API-8 FAQ

Specifications
Dimensions (LxWxH) 10" x 4.5" x 2"
Power Supply: Plug in 12 Volt AC adapter supplied
Programming Software: Pager Interface Programming Software (WIN3.1/95/NT Compatible)
Direct Connect Paging Protocol: TAP, PET
Direct Connect Paging Settings: 1200 Baud, E,7,1
Contact Inputs: 8 Optically Isolated Dry Contact or Wetted Voltage
Message Size: Max. 80 Characters/input/condition, maximum 256 characters per ASCII Event String
Incoming Data Type: RS232, ASCII Characters
Incoming Data Protocols: RS232, TAP, COMP2
Incoming Data Comm. Settings: N,7,1 or E,7,1 or N,8,1 (programmable), 600-9600 Baud
Telephone Line Connector: RJ11
Dial Up Number: Up to 25 Characters (programmable)
Dialing Method: DTMF
Messaging System Protocols: TAP 1.8
Back To API-8/232 Page

9011 Leslie Street Unit # 102, Richmond Hill, ON. L4B 3B6
Telephone: (905) 889-6511 Fax: (905) 889-6235
E-MAIL: monitor@mtca.com